The Band Scanner 2 is a revolutionary device that builds on the features of the legendary Band Scanner to provide you with the ultimate tool to assess FM broadcast band congestion and log station identification parameters. In keeping with the characteristics of its famous predecessor, this impressive tool can measure RF level, MPX deviation, Left & Right Audio Levels, RDS and Pilot injection levels. During a campaign, measurements are stored in a log file, after which they can be easily converted into KMZ format and visualized in Google Earth.
To power the system, all you need is the USB port of any Windows PC. With the Band Scanner 2 you can view playlists of the competitive stations, as well as save and export them into and Excel file. The free-of-charge Windows software sweeps the receiver across the FM band and generates a spectrum display of carrier level versus frequency. Each carrier is analyzed and a station list is created. This sophisticated product further refines stations with an RDS presence to show all radio data groups transmitted. It allows for manual tuning through the receiver screen or by double-clicking a point on the spectrum plot or an entry on the station list. There are two ways to save spectrum plots – as jpeg or bmp files. A separate window on the receiver screen displays the RDS data error level.
To proste, ale wielofunkcyjne urządzenie: mierzy poziom RF, dewiację MPX, moc MPX, poziomy audio kanałów L i P, poziom pdnośnej z kodera stereo. Wyniki pomiarów są stale i synchronicznie odświeżane pozwala to na szczegółowe odczyty wartości składników sygnału FM. Z DB44 można połączyć się poprzez Ethernet i opcjonalnie modem GSM, co umożliwia monitoring sygnału i odsłuch audio stacji w dowolnym miejscu i z użyciem (prawie) dowolnego smartfonu.
- W pełni oparty o DSP
- Pomiar mocy sygnału MPX (z historią zmian)
- Analizator widma RF z oscyloskopem pozwala sprawdzić parametry nośnej
- Analizator widma MPX z oscyloskopem
- Zmienna deemfaza – 50µs / 75µs
- Dekoder stereo z sygnalizacją obecności pilota
- Dekoder RDS i RBDS z BER meter
- Konfigurowalne alarmy dla RF, dewiacji, pilota i RDS dostępne przez e-mail, SMS (po podłączeniu modemu GSM), SNMP
- Kanały lewy i prawy demodulowane osobno
- Możliwość zdalnego nasłuchu poprzez sieć (streaming na żywo)
- Wbudowany serwer www z intuicyjnym interfejsem do zdalnego zarządzania
- Wejście antenowe o maksymalnym poziomie wejściowym do 90dBµV
- Kompaktowa, trwała i odporna elektromagnetycznie obudowa
RF INPUT | |
Frequency Range | 87.0 to 108 MHz, Frequency Agile |
Step Increment | 50 kHz |
Antenna Input | 50 Ω, BNC Connector, 10 dBµV sensitivity |
Internal Attenuator | 0, 10, 20 and 30dB, auto |
Dynamic Range | 0 dBµV to 100 dBµV |
S/N | 57dB, RF > 60dBµV, 30dB, RF > 10dBµV |
METERING RESOLUTION & ACCURACY | |
RF Level | 0 to 95 dBµV; resolution – 0.1 dBµV; accuracy – ±1 dB (10 to 85 dBµV) |
Multipath | 0 to 100%; accuracy – ±1% |
MPX Deviation | ±120 kHz; resolution – 0.1kHz; accuracy – ±10%, ±5% typically |
MPX Power | ±12 dBr; resolution – 0.1dBr, 10 sec. integration; accuracy – ±0.2 dBr |
Audio Level | -50 to +5dB; resolution – 0.1dB; accuracy – ±5% |
Pilot Level | 0 to 12 kHz; resolution – 0.1 kHz; accuracy – ±0.5 kHz, 1 to 12 kHz |
RDS Level | 0 to 9 kHz; resolution – 0.1 kHz; accuracy – ±10% typical and not guaranteed |
Audio, MPX, Pilot, RDS levels | |
Validity | RF level preferably > 50dBµV |
Multiplex Level | Peak level, 256 ksamples over 1 sec. |
Audio Level | Peak level, 64 ksamples over 1 sec. |
Pilot Level | Mean peak level, 256 ksamples over 1 sec. |
RDS Level | Mean peak level, 256 ksamples over 1 sec. |
STEREO DECODER | |
Stereo Separation | >25dB, typical >30dB |
De-emphasis | 50 or 75µs, Selectable |
THD | 0.5% |
OUTPUTS | |
Audio stream | Icecast/Shoutcast compatible audio stream |
Alarms | E-mail, SMS, SNMP |
Headphone | 1/8″ (3.5mm) Phone Jack |
GSM Modem | 15-pin Male D-Sub Connector |
RDS DATA DECODING | |
Standards | European RDS CENELEC; United States RBDS NRSC |
Error Correction & Counting | Yes |
AF Decoding | Yes |
CT (Time/Date) | Yes |
PI, PTY, DI, MS | Yes |
TA/TP | Yes |
RT (Radio Text) | Yes |
PS (Program Service name) | Yes |
FFT SPECTRUM ANALYSIS | |
Input | Composite MPX, Audio |
Dynamic Range | 80 dB |
FFT Length | 1024 |
Sampling Rate | 256 kHz – Composite, 64 kHz – Audio |
SCOPE ANALYSIS | |
Input | Composite MPX, Audio |
Trigger Mode | Auto, Fall |
Dynamic Range | ±120 kHz |
Sampling Rate | 256 kHz – Composite, 64 kHz – Audio |
USER INTERFACE | |
Web interface | Full monitoring and control; Interactive and easy to use |
Indicators | 3 LEDs (on front panel) |
Headphone Output | 1/8″ (3.5mm) phone jack (on front panel) |
TCP/IP COMMUNICATION | |
Type | Ethernet 10/100M Base-T Port |
Connector | RJ45 (on rear panel) |
OPERATING CONDITIONS | |
Temperature | 10° to 60°C |
EMC Immunity | 6V/m |
POWER REQUIREMENTS | |
Voltage | External, 12V/1A |
SIZE AND WEIGHT | |
Dimensions (W;H;D) | 125 x 31 x 160 mm |
Shipping Weight | 270 x 54 x 230 mm / 1.1kg |